EnviroCells

project

The sample environments and their infrastructures are mostly dedicated to individual beamlines at the APS. An overview of solutions for various in situ and operando applications is given here and will be continuously expanded _ [reference:01].

Content

About

Meetings - Every 4th Thursday of the month in Building 401/Room A1100, sample environments and their infrastructures are discussed addressing specific topics. Contributions in the form of 1-10 slides are welcome. The slides will be added to the collection.

Mailing List - Subscribe to the mailing list to receive the latest information, find competent contacts, and participate in discussions. If you want to send an email, the address is: sei-forum@lists.anl.gov

FAQ - Frequently asked questions will be collected for fast access to potential solution

For general information or suggestions, please contact Uta Ruett.

You can also get in touch with Ivan Kuzmenko and Phil Ryan.

Environment Cell

Furnace

Type Temp. Range Atmosphere Image Commercial Contact Loan Info  
Blower up to 1000 °C Helium   No Peter Eng No Simple to build 1
Blower up to 650 °C Air 00002 Yes: Leister LE MINI Wenqian Xu Ask box link 0002 2
Flow Cell up to 1000 °C Yes 00003 No Kevin Beyer Yes, if not in use box link 0003 3
Flow Cell up to 1000 °C Yes 00004 No: made of commerical parts Leighanne Gallington Yes, if not in use box link 0004 4
Batch ~ 450 °C Air 00005 No: NMR tubes as capillaries in a steel block Leighanne Gallington Yes, if not in use box link 0005 5
Flow Cell up to 1150 °C Yes   No: capillaries connected to gas system Matt Frith Yes, if not in use Flow cell with spinner 6
Infrared up to 1100 °C Air 00007 No: general purpose, bulk solid material Jun Sang Park bulky, difficult to move box link 0007 7
Linkham TS1500 up to 1300 °C Yes 00008 Yes: small solid material John Okasinski Yes, if not in use box link 0008 8
Induction up to 1500 °C Air 00009 No: very fast heater, conductive material Andrew Chuang Hard to move box link 0009 9
Induction up to 1000 °C Air 00010 No: water cooled Pavel Shevchenko Ask box link 0010 10
Induction up to 1500 °C Air 00011 Yes: THM 200 heater, BK power supply, PTC 10 controller, 3 AWG welding wires, plus custom water cooler Alex Deriy Ask box link 0011 11

Press

Type Temp. Range Pressure Image Commercial Contact Loan Info  
VX-3 Paris-Edinburgh up to 2000 °C 0.1-7 GPa p00001 Yes Ross Hrubiak No box link p0001 1

Liquid

Type Discharge (ml/min) Image Notes Contact Loan Info  
Peristaltic 0.45 l00001 commercial Model RP Q1 Ivan Kuzmenko No box link l0001 1
Peristaltic 100 l00002 commercial PRODUCT ID 1150 Ivan Kuzmenko No box link l0002 2
Custom see info l00003 see info Cunming Liu No box link l0003 3
Flow cell see info l00004 room temperature Xiaobing Zuo No box link l0004 4
Flow cell see info l00005 4-80 °C Xiaobing Zuo No box link l0005 5
Syringe pump see info l00006 commercial Hamilton microlab 600 Xiaobing Zuo No box link l0006 6
Syringe pump see info l00007 commercial Multi valve Tricontinent Xiaobing Zuo No box link l0007 7
Custom see info l00008 auto sampler (see info) Xiaobing Zuo No box link l0008 8

Cryostat

Interfaces

Type Temp. Range Atmosphere Image Commercial Comment Contact Loan Info  
MBE 30K to 1600K UHV 00001 No permanent setup in 33-ID Hawoong Hong No box link 0001 1
Humidity Chamber 15 to 50 °C Air+ RH 10-95% 00002 Yes: ETS model 5503   Chris Benmore No box link 0002 2
Fluid-Solid Cell up to 350 °C No 00003 No high pressure up to 40 MPa Changyong Park Maybe, please ask box link 0003 3

Infrastructure

Cabinets

List here all cabinets

Location Available Contact Comment
438 yes    

Analyzer

List here all analyzers:

Location Available Contact Comment
438 yes    
Analyzer one
Analyzer two

Pumps

List here all pumps

Location Type Contact Comment
438 turbo    
Pump one

more detailed description with photos, links to manual etc.

Pump two

Glove Box

List here all glove box

Location Available Contact Comment
438 yes    
Glove Box one
Glove Box two

Contribute

If you are familiar with sphinx readthedocs and github you can add a new environment cell or infractructure Envirocells by starting a new pull request.

If you are not familiar with these tools send an email to sei-forum@lists.anl.gov including a description using this template and a pull request will be opened for you.

References

[B1]Happy J and Unhappy J. The best furnace on earth. Journal of Synchrotron Radiation, 121(16):1224–1230, 2025.